The Multi-parameter analyzer can be widely used in urban or rural water supply plants, tap water pipeline networks, tap water secondary water supply, user taps, indoor swimming pools, Online monitoring of water quality such as large-scale water purification equipment and direct drinking water is an indispensable online analysis equipment in the fields of water plant production process control, water conservancy and water management, and sanitation supervision.

Characteristics

PH / ORP : 0 – 14 pH, ± 200 0mV.

Turbidity : 0 – 1 NTU / 0 – 20 NTU / 0 – 100 NTU / 0 – 4000 NTU.

Conductivity : 1 – 2000 uS / cm / 1 ~ 200 mS / m.

Dissolved oxygen : 0 – 20 mg / L.

Introduction

The Multi-parameter analyzer can be widely used in urban or rural water supply plants, tap water pipeline networks, tap water secondary water supply, user taps, indoor swimming pools, Online monitoring of water quality such as large-scale water purification equipment and direct drinking water is an indispensable online analysis equipment in the fields of water plant production process control, water conservancy and water management, and sanitation supervision.

Specification
ItemIndexValue
SystemWorking power (220 ± 22) VAC, (50 ± 1) Hz
Power30 W
Cabinet size800 mm * 506 mm * 180 mm (Standard version)
WeightAbout 15 Kg
Storage temperature 4℃ ~ +50℃
Working temperature4℃ ~ +50℃ / -25℃ ~ +50℃ (Optional temperature control heating antifreeze module)
Working humidity≤ 95% RH (No condensation)
Inlet flow500 - 1000 mL/min
Inlet pressure< 3 kg/cm³
Communication interfaceRS485 Modbus RTU communication protocol + wireless interface
TurbidityRange0-1 NTU / 0-20 NTU / 0-100 NTU / 0-4000 NTU
Resolution0-1 NTU / 0-20 NTU / 0-100 NTU : 0.001 NTU 0-4000 NTU : 0.01 NTU
Lower detection limit 0.02 NTU , 0.1NTU (0-4000 NTU)
Zero drift≤ 1.5%
Indication stability≤ 1.5%
Accuracy2% or ± 0.02 NTU, 5% or 0.5 NTU (0-4000 NTU)
Repeatability≤ 3%
Response timeT90 ≤ 120s
Recommended maintenance period3 - 12 months (Depending on the water quality on site)
Residual chlorine / chlorine dioxideRange0 - 5 mg/L / 0 - 20 mg/L
Resolution0.01 mg/L
Lower detection limit 0.05 mg/L
Accuracy± 0.05 mg/L or ± 5% (DPD comparison error ± 10%)
Response time≤ 120 seconds
Recommended maintenance period1 - 3 months or weekly calibration, 3-6 months to replace consumables
PH /ORP (Optional)Range0-14 pH, ± 2000 mV (ORP)
Resolution 0.01 pH, ± 1 mV (ORP)
Accuracy± 0.1 pH, ± 20 mV (ORP) or ± 2%
Repeatability± 0.1 pH, ± 10 mV (ORP)
Response time≤ 60 seconds
Recommended maintenance period 1 - 3 months
TemperatureRange0℃ - 50℃
Resolution0.1℃
Accuracy± 0.5℃
Repeatability≤ 0.5℃
Response time≤ 25 seconds
Recommended maintenance period12 months
Conductivity (Optional)Range0 - 2000 uS/cm
Accuracy± 1.5% FS
Repeatability≤ 0.5% FS
Response time≤ 30 seconds
Recommended maintenance period 3 - 6 months
Dissolved oxygen (Optional)Range0 - 20 mg/L
Accuracy± 0.3 mg/L
Repeatability≤ ± 1.5%
Response time≤ 30 seconds
Recommended maintenance period1 - 3 months
Expansion portPort typeRS485, 4 - 20 mA
Cart
  • Your cart is empty Browse Shop
    Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
    • Image
    • SKU
    • Rating
    • Price
    • Stock
    • Availability
    • Add to cart
    • Description
    • Content
    • Weight
    • Dimensions
    • Additional information
    Click outside to hide the comparison bar
    Compare