INATEC – TRC-400 Residual Chlorine Meter

INATEC – TRC-400 Residual Chlorine Meter

INATEC – TRC-400 Residual chlorine meter has a built-in sensor, which has the characteristics of high measurement accuracy, fast response time and low maintenance cost.

Characteristics

Measure range :

Residual chlorine : (0 ~ 5) mg/L.

Temperature : (0.1 ~ 40.0)℃.

Load Resistance : ≤ 750 Ω.

Power supply : 220 VAC.

Communication : MODBUS RS485.
Features

​​​​​​The residual chlorine meter has a built-in sensor, which has the characteristics of high measurement accuracy, fast response time and low maintenance cost. The residual chlorine meter outputs 4 ~ 20 mA standard signal and RS485 signal, which can be connected to various regulators, and can be connected to two-position regulators, time proportional regulators, non-linear regulators and classic PID regulators according to requirements, which can be combined into various types. Residual chlorine control system.

  1. The electrode measurement is accurate and the response speed is fast.
  2. LCD with backlight, easy and intuitive operation.
  3. With automatic temperature compensation, pH manual compensation function.
  4. Restore factory function to avoid data loss by misoperation.
  5. Isolated 4-20mA standard signal can realize signal remote transmission.
  6. Range can be switched manually.
  7. A variety of calibration methods are convenient for on-site adjustment.
INATEC – TRC 400 Residual Chlorine Meter
InformationSpesification
ProductResidual Chlorine Meter
ModelINATEC - TRC 400
Measure rangeResidual chlorine : (0 ~ 5) mg/L Temperature: (0.1 ~ 40.0) ℃
Display7 inch touch screen
Protective box sizeDimensions: 400 mm × 300 mm × 200 mm Window size : 155 mm × 87 mm
Transmit output(4 ~ 20) mA (Optional)
Load resistance≤ 750 Ω
Communication RS485, Modbus
Environmental humidity≤ 95% no condensate
Power supply220 VAC
Ingress protectionIP43
INATEC – ERC 400 Residual Chlorine Meter
InformationSpesification
Measurement contentHCLO、CLO2
Measuring system Microelectronics MEMS technology, special membrane structure
Measure range(0 ~ 5) mg/L
Accuracy When ≤ 0.1 mg/L, the absolute error is ± 0.01 mg/L, When ≥ 0.1 mg/L, ± 5 % of the measured value or ± 0.02 mg/L (Whichever is greater)
Resolution0.01
Polarization timeWhen using for the first time, first pass water for 2 hours in chlorinated water, and then power on for half an hour
Response timeLess than 30s after polarization is completed
Minimum conductivity ≥ 100 us/cm, can not be used for ultrapure water
Operating temperature(0 ~ 40) ℃ (Non-condensing)
Temperature compensationPt1000 with built-in integrated automatic compensation
Max pressure4 bar
Recommended flow rate≥ 0.03 m/s in flow cell
pH range(5 ~ 9) pH, below 5 will damage the membrane head
Maximum chlorine concentration≥ 5 ppm
Power supplyStandard 24 V DC ± 2V, optional 12 V DC ± 2 V
Power consumption 1.56 W
Digital communicationMODBUS RS485
Cable lengthStandard 3 meters, others can be customized
Probe weight210 g
Thread sizeNPT 3/4
Connection method 5-pin waterproof aviation plug
Moisture-proof materialPVC and Viton ® O-ring seals
Cart
  • Your cart is empty Browse Shop
    Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
    • Image
    • SKU
    • Rating
    • Price
    • Stock
    • Availability
    • Add to cart
    • Description
    • Content
    • Weight
    • Dimensions
    • Additional information
    Click outside to hide the comparison bar
    Compare